Last Update: March, 2011
1. New Features
1.1 New WipSoft Features 1.2 New Location Features
1.1 New WipSoft Features
1.2 New Location Features
2. Software Release Description
2.1 Software Identification 2.2 Compatibility 2.3 Software Installation
2.1 Software Identification
2.2 Compatibility
2.3 Software Installation
3. Known restrictions
3.1 Extended AT specific restrictions 3.2 WipSoft restrictions 3.3 Location AT restrictions
3.1 Extended AT specific restrictions
3.2 WipSoft restrictions
3.3 Location AT restrictions
4. Interface modifications
4.1 WipSoft 4.2 Location AT
4.1 WipSoft
4.2 Location AT
5. Corrections & Improvements
5.1 WipSoft 5.2 Location AT
5.1 WipSoft
5.2 Location AT
The Extended AT 1.01 Application offers, in a single application, the combination of all WIP and GPS AT commands provided by:
Software Identification
Extended AT Plug-In Package
1.1.0.201103081445
Version string reported by the Wip Plug-In (AT+WIPCFG=3)
WIP Soft v541 on Open AT OS v635
Jan 28 2011 09:29:52 WIPlib:v5a35 WIPSoft:v3b25
Version string reported by the Location Plug-In (AT+GPSVERS?)
GPS-LocLib.1.1.0-Mar 2 2011-14:04:23-
SiRFHostIV-4.0.2-B17c1c GSD4t_4.0.2-B17_16x 08/27/2010 300
Air Prime™ Intelligent Embedded Module compatibility list
WMP1x0 / Q268xG / Q268xRD / SL6087
IMPORTANT: Due to memory constraints,
Firmware compatibility
Firmware 7.45
Tools compatibility list
Developer Studio: 1.2.0 or later
Tool chains: RVDS (ARM_ELF_GCC not supported)
To download the Extended AT Application, you must install the software package using Sierra Wireless’ Developer Studio 1.2.0 or later.
The download menu is directly accessible from Installed package view.
The specific Extended AT known restrictions of this release are:
Id
Description (What / When)
Impacted Domain
Impacted
Sub Domain
59464
As WIP Ethernet driver and Location GPS share common resources, the Ethernet bearer should not be opened (AT+WIPBR=1,4) after GPS initialization (AT+GPSINIT).
OTHER
60393
60399
Reset happens when upload /download FTP file while GPS running with I2C.
60309
When receiving data in Data Offline mode using WIPSoft, some unsolicited responses are getting missed until an AT command is issued.
DEVICE
V24
60277
WIP_BEV_IP_DISCONNECTED not received by the WIP application in case a GPRS session is active and a network loss occurs.
58386
Embedded module may reset while transferring MMS with file greater than 6KB in "chunked data transfer encoding".
56385
Ethernet bearer cannot be started once the Ethernet cable is unplugged and plugged again.
56165
If the network is lost (+WIND: 8 is received) between bearer start and reception of bearer connect event , WIP is no more responsive and no event exchange takes place.
56164
The Embedded module may reset when network connection is lost during GPRS bearer stop operation.
55472
The +++ sequence is not sent as data on setting the value of option AT_WIP_NET_OPT_ESC_SEQ_NOT_SENT as 0. Ideally +++ sequence should be transmitted along with data to the peer after issuing command "at+wipcfg=2,13,0".
55094
Ethernet bearer cannot be reopened after restarting the IP Stack.
55029
When an FTP server is established on UART PPP bearer, reset is observed while closing the stack without first closing the bearer.
55021
It is not possible to start the Ethernet bearer with DHCP enabled. Also with DHCP disabled, the Ethernet bearer does not get unsubscribed on removing the Ethernet cable.
54402
Sometimes the embedded module stops responding if the stack is closed before closing the open ethernet bearer.
52919
When file containing only DLE ETX character sequence is sent from TCP client to the server then data loss occurs and "SHUTDOWN" indication is received.
WIPLib
52499
Incorrect error codes are received when invalid peer IP address is given while trying to establish TCP Server Client connection.
58187
When in GPS_SLEEP state, sleep request (AT+GPSSLEEP=X) is rejected. It is required to go to GPS_INITIALIZED state to change sleep mode.
GPS AT cmd.
Sleep mode
59165
GPS_SLEEP state is not restored after AT+GPSSAVE=1 and +CFUN=1.
60361
Inconsistent number of sentences indicated in PVT:3 in 6SV case: 2 is indicated, whereas only 1 sentence is present.
PVT
60184
60186
The number and indication of Satellites in View Used for Navigation are not consistent in the +GPSPVT event. All satellites in view are considered as used for navigation.
60442
The GPS_ABORT_EVENT events are never indicated and GPS_START_ERROR_EVENT event is not sent in case of failure after a first successful GPS start.
60107
In I2C configuration, Location Plug-In is not compatible with AirPrime module W32K sleep mode.
I2C
60273
Raw data is not compatible with CMUX protocol use.
GPS AT cmd
60552
The longitude value reported in +GPSPVT:1 sentence is not correct for values superior or equal to 100°
GPS_AT_cmd
Please refer to WipSoft new Features paragraph.
Backward
Compatible
Change
Comments
Yes
+GPSCONF new supported values for host wakeup mechanism option
+GPSINIT new supported values for I2C hardware configuration
+GPSINIT=12 is made obsolete. Must use +GPSINIT=11 instead.
Value still supported in this release, but may be removed in future releases
No
PDOP and VDOP fields support (for both PVT and NMEA frames)
New Geoidal separation field on §GPGGA frame
Issue Description
Fixed In
43781
+CME ERROR:841 is received instead of +WIPPEERCLOSE when FTP session is closed by peer.
WIP 5.41
56102
No +WIPFILE indication received when using HTTP_POST method in AT+WIPFILE wipsoft command.
58000
+WIPPEERCLOSE indication is not received on closing the FTP channel manually using the command AT+WIPCLOSE=4,<idx>
59518
A new option has been added in AT+WIPBR to return detailed CME Error codes or a generic error (+CME ERROR: 812) in the case of GPRS set up is failure.
59551
Reset is observed if an attempt is made to establish a POP3 session over an index value greater than 9 using the AT+WIPCREATE command.
57579
After the local SIM is removed and the remote SIM is inserted while GPRS setup is in progress, the WIP bearer startup for the remote SIM fails and no notification or WIP plug-In event is sent for the same.
58253
When SIM is removed, WIP_BEV_STOPPED event is not sent out when GPRS bearer is started using WIP.
50608
In the case of GPRS set up is failure, WIP now returns specific error codes instead of a generalized event (WIP_BERR_GPRS_FAILED).
52249
The "+WIPPEERCLOSE" unsolicited indication is not received when the FTP channel is closed by the server due to time out.
54171
When an error is generated on a TCP Channel, wip_getOpts() returns the correct error code in WIPLib but error code is not correctly displayed by WIPSoft.
56731 58865
Reconnecting to the Embedded module from Windows PC using PPP bearer fails even when WIP_BOPT_RESTART is set TRUE . Windows pops up Error:777 after attempted to reconnect.
59853
Ethernet controller may not be stable when AHB (Advanced High-performance Bus) clock of the Embedded module is increased from 26Mhz to 52 MHz (using AT+WCPS). This is because the C-Ethernet plug-in SPI bus runs at 26MHz instead of 13MHz but the Microchip chip supports only upto 20MHz.
57526
+CME ERROR: 847 is not received when the timer expires while trying to connect to GPRS bearer using WIPSoft.
WIP 5.40
57583
Peer port is displayed as 0 in +WIPDATA indication for UDP protocol.
56324
OK is not displayed when socket command subscription is successful.
57230
To prevent data corruption, MMS Transaction ID buffer has been increased from 10bytes to 11bytes.
57462
Repeated GPRS bearer start and stop along with stack open and close leads to module reset.
57504
User receives +CME ERROR:847 and bearer gets disconnected when AT+WIPBR=4,6,0 command is given at the time GPRS bearer is already connected. Ideally, only +CME ERROR:803 should be received and not followed by +CME ERROR:847, when user attempts to start the GPRS bearer at the time the bearer is already connected. The GPRS bearer should not get disconnected after 2 minutes on such an attempt.
WIP 5.32
54436
On giving the command AT+WIPBR=2, 6, <opt num>, <value> where <opt num>=12/13/14/20 and value=alphabet/negative, user receives +CME ERROR: 800 instead of +CME ERROR: 801.
WIP 5.31
56360
WIP_BERR_NO_DEV error is received while opening Ethernet bearer with RVDS binary. It works fine with GCC compiled binary. User should not get this error irrespective of compiler being used i.e. GCC or RVDS.
56883
Creating and closing the HTTP sessions consecutively for sometimes causes Embedded module to reset. This is due to memory leak while opening and closing the HTTP Sessions.
53515
It is not possible to send data through UDP client socket in the continuous data mode, using WIPSoft application compiled on RVDS compiler. The Embedded module gets reset. Ideally, user should be able to exchange data over UDP socket using application compiled on any of the compilers: ADC/GCC/RVDS.
54615
When AT+WIPBR command is issued with "invalid value" for the option WIP_BOPT_LOGIN, OK response is received instead of +CME ERROR: 801. Note that this command is given after starting the stack (AT+WIPCFG=1) and opening the particular bearer (AT+WIPBR=1, 6).
54984
The user cannot retrieve the IP address values set through +WIPBR command, before or after starting the bearer. Ideally, the user should be able to retrieve the IP related values after starting the bearer.
55050
Using WIPSoft, the unsolicited indications +WIPDATA, +WIPACCEPT, +WIPFILE and +WIPREADY are not received on all the ports opened (USB, CMUX and UARTS). Ideally, these unsolicited indications should be received at all open ports.
53459
When wip_putfile () API is provided with invalid file path for FTP protocol, the event WIP_CEV_OPEN followed by WIP_CEV_WRITE event are received in the file data handler. The ideal behavior should have been receiving WIP_CEV_ERROR in file data handler. Note that, this behavior is observed only in passive mode of FTP and not in case of active mode FTP.
WIP 5.30
53549
The "WIP_BEV_STOPPED" event is not received when Ethernet bearer is stopped using wip_bearerStop () API.
54452
After activating PDP context with CID 1 with WIP bearer APIs, then the dialing ATD*99**2# with CID 2 freezes the dialing process. It is not possible to open another PDP context when bearer is started using WIP Plug-In.
54671
It is not possible to perform operations such as set or get options through an Embedded application, compiled with RVDS compiler. The error -998 is received from WIP Library. Ideally user should be able to perform the above operations on RVDS also, as already being able to successfully perform on other two compilers: GCC and ADS.
54982
User will not be able to create a socket after starting the Ethernet bearer, when DHCP is disabled. Ideally, user should be able to create a socket for both the cases: DHCP enabled or disabled.
55022
It is not possible to create a socket after starting the Ethernet bearer, "+CME ERROR: 803" is attained. Ideally the user should be able to create a socket after starting Ethernet bearer, irrespective whether DHCP is enabled or disabled.
56419
When mail is downloaded using POP3 protocol and WIPSoft application, data gets corrupted. Some characters are missing from the downloaded mail.
58773
Debug UART remains subscribe in Data mode when AT+GPSDEBUG=0,X is entered
Location 1.1
59281
The AT+GPSINIT response is not received immediately through the virtual port (CMUX) used to send the AT command until new AT command is sent in the same virtual port.
59418
The configuration of the navigation low power mode is not functional in GPS_INITIALIZED and GPS_SLEEP state. This configuration should be applied in the GPS_RUNNING state through the gps_coreSetOpts function or the AT+GPSCONF=0,X command.
59369
When start from the state GPS_SLEEP / GPS_HIBERNATE_MODE is failed, any next start will always fail. The Location Plug-In should be stopped in this case before the restart.
59317
The AEE feature not activated if a first gps_start was previously done with AEE option disabled. Embedded Module reset is then required.
59423
The Satellites in View Signal To Noise Ratio of the PVT service is not consistent when the Very Low/Low/Medium power navigation modes are activated. The field statsInViewSNR of the PVT structure gps_pvtSatInViewInfo_t is not consistent. The fields 8/11/14/17/20 of the PVT sentence number 3 are not consistent.
58578
Location Plug-In is not compatible with AirPrime module W32K sleep mode
57781
AT+GPSNMEA=2 generates a WCPU reset due to conflict on UART 2 (used for GPS companion communication).